BW/HR/FR membrane element can be used in salt concentration within 2000-8000ppm of raw water desalination treatment.
Widely used in urban sewage, chemical wastewater, paper wastewater, printing and dyeing wastewater, leather wastewater,
food processing wastewater, electroplating wastewater, garbage osmotic liquid and other fields of water reuse projects
Membrane element operating limits:
Maximum Operating Pressure: 600PSI
Maximum Inlet Temperature: 45℃
Maximum Inlet Flow: 17m3/h(8040),3.6m3/h(4040)
Maximum residual chlorine concentration: 0.1mg/L
Influent PH range during continuous opertation: 3-10
PH range of inlet water during chemical cleaning: 2-10
Standard test condition:
Test Fluid Type: 2000ppm Nacl
Pressure Test: 225PSI
Test Fluid PH: 7.5-8
Test Fluid Temperature: 25℃
Recovery: 15%
MODEL | FLOW | REJECTION (%) | INPUT TDS (ppm) | PRESSURE (psi) | RECOVERY (%) |
BW-4040-HR | 2400 | 99.5 | 2000 | 225 | 15 |
BW-8040-HR | 10500 | 99.5 | 2000 | 225 | 15 |
BW-4040-FR | 2000 | 99.7 | 2000 | 225 | 15 |
BW-8040-FR | 9500 | 99.7 | 2000 | 225 | 15 |
SW-2521 | 300 | 99.7 | 32000 | 800 | 8 |
SW-2540 | 600 | 99.7 | 32000 | 800 | 8 |
SW-4040 | 1800 | 99.7 | 32000 | 800 | 8 |
SW-8040 | 8500 | 99.8 | 32000 | 800 | 8 |